Product

Contact us

Shandong Fengtu IOT Technology Co., Ltd

Sales Manager:Ms. Emily Wang

Cel,Whatsapp,Wechat:+86 15898932201

Email:info@fengtutec.com

Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China

location:Home>Products>Atmospheric monitoring>Odour Monitoring>Odor gas online monitoring system
Odor gas online monitoring system

Odor gas online monitoring system

Model:FT-EC04

Brand:fengtu

Odor gas online monitoring system can monitor the odor gas concentration in the environment in real time, including NH3, H2S, TVOC, and OU values.

1.Introduction to Odor gas online monitoring system

Odor gas online monitoring system can monitor the odor gas concentration in the environment in real time, including NH3, H2S, TVOC, and OU values.Odor gas online monitoring system is an odor concentration online monitoring system independently developed and produced by our company based on many years of experience in gas detection and atmospheric environment monitoring, in accordance with the "Emission Standard of Odor Pollutants (GB14554-1993)" and "Technical Specifications for Odor Pollution Environmental Monitoring (HJ905-2017)", specifically for places prone to odor. It is commonly known as the odor electronic nose.

Concept of bad smell:

Malodor refers to any gaseous substance that stimulates the olfactory organ and causes discomfort to people and damages the living environment. There are many types of malodors. So far, there are more than 4,000 types that can be sensed by human sense of smell, among which there are dozens of types that are more harmful to human health.

Scenes where the stench appears:

Science and technology parks, chemical parks, landfills, waste treatment stations, waste power plants, waste incineration sites, chemical plants, farms, sewage treatment plants, pharmaceutical plants, breweries, energy and power companies, textile factories, urban and rural residential areas, scientific research institutes and universities, etc.;

Odor gas online monitoring system Alias:

Electronic nose, odor gas detector, odor gas online monitor, Odor gas online monitoring system, odor electronic nose, odor concentration online monitoring system, odor electronic nose concentration monitoring system, filter type odor detection system, odor OU monitoring system, odor concentration online monitoring system, odor electronic nose monitoring system, odor concentration electronic nose system, OU value online monitoring system, odor detection analyzer;

2. Odor gas online monitoring system product introduction

Odor gas online monitoring system consists of power supply system, gas collection system, sensor monitoring system, data control system, display and transmission;

Odor gas online monitoring system adopts a unique compensation and anti-interference algorithm. The system uses array sensors. In addition to detecting three major categories (S series, N series, and VOCs series) according to national standards, the main monitoring parameters include ammonia, hydrogen sulfide, trimethylamine, carbon disulfide, methyl mercaptan, styrene, methyl sulfide, dimethyl disulfide, 8 kinds of gas substances, single gas and composite odor concentration OU values, a total of nine parameters.

Four conventional parameters for online odor monitoring: NH3, H2S, TVOC, and OU value;

Power supply system: Mains power supply conversion system

Gas collection system: The air in the environment is drawn into the gas collection chamber (sniffing bag) for detection and analysis through a sampling pump and a gas collection rod (including a flow control unit);

Monitoring system: gas sensor detection module, meteorological parameter detection module, responsible for the identification and analysis of different odor components in odor samples; sensor array design, integrated multi-gas cross-interference algorithm, temperature and humidity compensation algorithm control system: the control unit collects the detection data of each sensor, and uses the big data model to analyze and calculate to obtain accurate data;

Display system: presents the collected and processed data of each monitoring factor in an easy-to-understand manner; the chassis is integrated with a 7-inch high-definition color screen, which can be equipped with an external LED display screen or a large-screen control center;

Transmission system: The transmission unit uses DTU or data acquisition instrument (2-channel 232 interface, 3-channel 485 interface, 2-channel Ethernet interface, other interfaces are optional), transmission protocol J212; data can be displayed on the smart environmental protection supervision platform, the platform specified by the demander, the environmental protection bureau platform, etc.

Odor gas online monitoring system

3. Features of Odor gas online monitoring system

Gas monitoring parameters: ammonia, hydrogen sulfide, trimethylamine, carbon disulfide, methyl mercaptan, styrene, methyl sulfide, dimethyl disulfide; dimensionless OU value Meteorological monitoring parameters: temperature, humidity, wind speed, wind direction, air pressure, light, noise, etc.

Product Name

Odor gas online monitoring system

Product ModelFT-EC04
Sampling method

Pump Suction

Supported parameters

Odor monitoring standard parametersIntegration options
Ammonia0-10ppm0.01ppmElectrochemistrytemperature-40~120℃0.5℃Meteorological integration (ultrasonic)
Hydrogen sulfide0-2ppm0.001ppmElectrochemistryhumidity0.05~100%RH0.05%RH
Methyl sulfide0-10ppm0.01ppmElectrochemistrywind direction0~359°
Methyl mercaptan0-10ppm0.01ppmElectrochemistryWind speed0~30m/s0.1m/s
Carbon disulfide0-10ppm0.01ppmElectrochemistryAir pressure10~1200bmar1bmar
dimethyl disulfide0-10ppm0.01ppmElectrochemistryillumination0~200klux0.1klux----
Sulfide0-10ppm0.01ppmElectrochemistrynoise20~130dB1dB----
Styrene0-10ppm0.001ppmPID PhotoionizationPM2.50~1000ug/m31ug/m3Laser scattering
OU value0-100ou1ouArrayPM100~1000ug/m31ug/m3Laser scattering

Features:

▲Customized design of intelligent modules:

9 target gases including OU value of odor, ammonia, hydrogen sulfide, trimethylamine, methyl mercaptan, methyl sulfide, dimethyl disulfide, carbon disulfide and styrene can be combined arbitrarily, with no limit on technical principle and detection range, and the sensor can be pluggable;

It also supports the monitoring of meteorological parameters, temperature and humidity, wind speed and direction, and atmospheric pressure.

▲Sensor array combination:

Compatible with electrochemical, PID, metal oxide semiconductor and other sensor technology principles Array cross-interference algorithm processing

▲Human-computer interaction interface, real-time display of monitoring data:

Industrial-grade high-definition 7-inch touch screen, monitoring data, change curves, historical data, alarm data and other operating systems display the real-time value, unit value, maximum value, minimum value and average value of monitoring indicators in real time

The historical data of any time period can be queried and displayed in curve graphs

▲Intelligent sensing technology, automatic identification and expansion

Built-in calibrated intelligent gas sensor, plug and play, automatic identification; sensor exclusive customized reaction gas chamber, target gas fully and effectively reacts to detection

By replacing different intelligent gas sensors, it is possible to detect gases other than the existing 4 gases. One machine has multiple uses, including imported vacuum pumps, multiple filter protection devices, and olfactory bags, providing a stable and steady airflow

▲Intelligent calibration and multiple data correction modes ensure data stability

Automatic zero point calibration, intelligent data temperature compensation, K value intelligent algorithm standard gas, target point remote calibration

▲Multiple signal output options

Provides various output modes such as RS485, 232, Ethernet port, USB port, GPRS, etc.

4. Odor gas online monitoring system configuration parameters

Configuration parameters of online odor monitoring analyzer
OriginChinabrandFengtu TechnologymodelFT-EC04
Serial numberConfiguration Nameunitquantityparameter
1Hosttower1Test items: ammonia; hydrogen sulfide; methyl mercaptan; methyl sulfide; dimethyl disulfide; carbon disulfide; styrene; odor concentration value OU value;
1.17 electrochemical sensors, 1 PID sensor;set1⑴、8 sensors corresponding to detection: ⑶、Ambient temperature: -20℃-+50℃. ⑷、Ambient humidity: 0-95%RH. ⑸、Detection cycle: the detection cycle and data upload frequency can be set in advance
1.2Smell bag sampling control deviceset1⑴ Injection flow rate: 400 ml/min, built-in sampling system. ⑵ Built-in sampling system: 1 built-in pump, four solenoid valves (sampling and zero gas). ⑶ 2000ml detachable air bag
1.3Backflush systemset11. Purge air circuit control solenoid valve 2. Activated carbon filter
2Data acquisition and transmission instrumenttower11. Output signal: RS232, GPRS, RS485, network port, U disk, etc.; 2. TCP network protocol, 212 protocol, data upload to 4 platforms including Environmental Protection Bureau 3. Remote control, remote setting, GPS positioning function
3Rainproof protection boxtower1⑴ Length*width*height: 500*300*600mm ⑵ Material: Plastic spraying

5. Odor gas online monitoring system configuration parameters

FT-EC04-2.jpg

Product Introduction and Application Fields

Portable Handheld Composite Gas Detector

(Also called portable composite gas analyzer)

It is a high-precision pump-type composite gas analyzer suitable for complex environment detection. It has built-in pre-processing, error compensation, anti-electrical interference, wireless signal output and other functions. The analyzer can detect up to 8 types of gas at the same time.

The portable gas detector has built-in optional wireless transmission and can be connected to the Ampal server to achieve functions such as remote monitoring, remote setting of alarm values and remote calibration.

Main purpose and scope of use: Suitable for all operating personnel including professional technicians, operators, leaders, etc.

Project ContentSpecific parameters
Product NamePortable odor gas detector
Detection gasComposite gas (NH3, H2S, TVOC, OU values can be combined arbitrarily, up to 8 types can be analyzed simultaneously)
Measuring rangeNH3: 0-2ppm; H2S: 0-20ppm TVOC: 0-20ppm; Odor value: 0-1000OU (range optional)
Display unitsppm, mg/m3, %VOL, %LEL (partially switchable)
ResolutionNH3:0.01ppm; H2S:0.01ppm; TVOC:0.001ppm; Odor value: 1 OU
Accuracy≤±2%FSSampling methodPump Suction
Response timeT90≤20(electrochemical); T90≤10(PID photoionization)Wireless OutputLORA, 433M, 800M, GPRS/3G/4G
Recovery timeT90≤25(electrochemical); T90≤10(non-dispersive infrared); T90≤30(catalytic combustion)Alarm methodSound and light alarm; vibration alarm; display character flashing and information reminder, etc. Visual alarm; alarm off optional
Drift≤±1%FS/yearBattery capacity3AH large capacity battery, overvoltage and short circuit protection function
PreprocessingBuilt-in dehumidification, dust removal and other pre-treatment, suitable for harsh environments such as high humidity and high dustCharging parameters5V 1A
Data analysisWith curve waveform analysis data display and data average statistical displayExplosion-proof typeIntrinsically safe
Display Mode5-inch high-definition color touch screenProtection level numberIP65, dustproof, splashproof, anti-static
System languageChinese (default) and English switchableService life2 years (sensor), 5 years (meter)
Communication interfaceDB9 serial port, USB interface, support USB hot plug, optional RS232 serial portData storageData storage comes standard with 300,000 data records, supporting local real-time viewing, deletion and data export
Shell materialABS engineering plastic + display stand alloy (anti-corrosion and anti-oxidation surface treatment).sizeOverall dimensions: 332×283×148mm
Temperature measurement-20℃~+500℃, accuracy ±0.2℃ (with temperature compensation function)weight≥1.5kg
Humidity measurement0~+100%RH, accuracy ±3℃ (with temperature compensation function)ConfigurationInstruction manual, certificate, warranty card, USB charger (including data cable), high-grade ABS engineering plastic box

6. After-sales service commitment

Serial numberAfter-sales service detailsRemark
1We guarantee that the quality, specifications and performance of the products are consistent with those described in the program documents.Quality requirements
2We are responsible for the quality of the purchased supporting parts and equipment. The material department should conduct strict quality inspection and provide the buyer with product quality certificates and technical documents related to installation and use upon delivery.Goods inspection
3During the warranty period, if the equipment fails to work due to a fault of the equipment itself, we will respond within 2 hours after receiving notification from the user and propose a repair plan within 4 hours.Warranty Service
4After the warranty period, we will continue to provide technical support for the use and operation of the equipment, including troubleshooting and the supply of spare parts. Within five years after the expiration of the free warranty period, the price of spare parts we provide is 70% off the market price.After-warranty service
5The training we can provide: Hardware installation, use and maintenance training; Basic physical properties theory training; Conventional sample testing method instructions, etc.Training content
6We will provide the operation manual, instruction manual, maintenance instructions, etc. of the equipment to the buyerTraining Materials
7We guarantee the clarity, completeness and accuracy of the technical documents provided, and provide timely technical documents that meet the requirements of equipment installation, operation, maintenance and overhaul.Training Materials
8Our technical experts provide guidance services for the installation and commissioning of the equipment. We are responsible for any losses caused by the supplier's guidance, design, and manufacturing quality during the installation process. If the buyer does not follow the guidance of the technical experts, the supplier is responsible for replacement and repair, and the cost shall be borne by the buyer.Installation Cooperation Requirements
9Warranty period: 1 yearWarranty period

Reasons to choose Odor gas online monitoring system:

1 Objectively evaluate odor pollutant emissions

For manufacturing enterprises, the emission or leakage of a small amount of odorous pollutants is inevitable during the production process. By installing the Odor gas online monitoring system, pollutant emissions can be monitored continuously for 24 hours. By using the over-standard alarm function in the system, pollutant over-standard situations can be discovered and dealt with in a timely manner. By analyzing real-time and historical data, summarizing patterns, discovering problems, improving enterprise management level, and ensuring that pollutant emissions meet national standards.

2. Response to residents’ complaints

When an odor pollution accident occurs, companies that have installed the Odor gas online monitoring system can take timely countermeasures to reduce the severity of the accident, give residents an appropriate explanation, and improve the harmonious relationship between companies and residents. Environmental regulatory departments use the odor monitoring system to conduct on-site monitoring of sudden odor pollution accidents, obtain monitoring results immediately, and inform companies and residents of the pollution situation on site, thereby improving the credibility of environmental protection departments.

3 Investigation of odor pollution sources

Enterprises that have installed the Odor gas online monitoring system can use odor monitoring data combined with meteorological monitoring data to exclude or determine whether the pollutants are emitted by themselves; environmental monitoring departments can use the odor monitoring system to establish a database of characteristic pollutants of enterprises within their jurisdiction. When an odor pollution accident occurs, the polluting enterprise can be quickly identified in combination with meteorological data.

4. Improve public image

4.1 Enhance the corporate public image and increase brand value

Through the installation of Odor gas online monitoring system, the occurrence of odor pollution accidents can be effectively reduced, and the surrounding residents can coexist harmoniously, responding to the national policy of "Green water and green mountains are gold and silver mountains". With appropriate media publicity, it can effectively enhance the corporate image, increase brand value, and also become a plus point for corporate financing.

4.2 Improve the credibility of environmental protection authorities

Timely handling of odor pollution accidents has always been one of the headaches for environmental protection regulatory departments. In the past, when there was a lack of effective monitoring methods, residents often mistakenly believed that the competent authorities were inactive and shielded polluting enterprises; while production enterprises believed that the regulatory authorities were blocking them and imposing fines indiscriminately, which had a negative impact on the government's image. Through the use of odor monitoring and analyzers, monitoring data can be given on site, clearly and effectively improving the credibility of regulatory departments.

Hello, my friend!What kind of support do you need? Our products is sure to satisfy you.
*Name
*Email
Phone
Country
*Message