Product
Recommended article
- The Intimate Link between Negative Oxygen Ion Monitors and Forest Tourism Resources
- Portable Weather Station: Your Pocket-Sized Environmental Companion
- FT-CQX5 Micro Weather Station: Meteorological Monitoring at Your Fingertips
- Essential Meteorological Parameters: The Foundation of Weather Forecasting and Climate Analysis
- Fengtu's Vehicle-Mount Weather Station: Air Pollution Monitoring Technology
- Harnessing the Power of Negative Oxygen Ions for Healthier Environments
Contact us
Shandong Fengtu IOT Technology Co., Ltd
Sales Manager:Ms. Emily Wang
Cel,Whatsapp,Wechat:+86 15898932201
Email:info@fengtutec.com
Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China
Carbon Monoxide Detector
Model:FT-QT1S
Brand:fengtu
Related products
1. Nitrogen dioxide sensor technical parameters
Carbon Monoxide detectors are usually installed in a specific location and are able to continuously monitor the concentration of carbon monoxide and transmit the data to the monitoring system.
model | Measurement parameters | Measuring range | Accuracy | Resolution | unit | Operating temperature | Operating humidity |
QT1 | Carbon monoxide | 0-1000PPM | ±2PPM | 1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
QT1S | 0-20PPM | ≤±5% | 0.01PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing | |
QT2 | Sulfur dioxide | 0-20PPM | ±1PPM | 0.1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
QT2S | 0-1PPM | ≤±5% | 0.001ppm | PPM | -20℃-+50℃ | 10-95%RH non-condensing | |
QT3 | Nitrogen dioxide | 0-20PPM | ±1PPM | 0.1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
QT3S | 0-1PPM | ≤±5% | 0.001ppm | PPM | -20℃-+50℃ | 10-95%RH non-condensing | |
QT4 | ozone | 0-20PPM | ±1PPM | 0.1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
QT4S | 0-1PPM | ≤±5% | 0.001ppm | PPM | -20℃-+50℃ | 10-95%RH non-condensing | |
QT5 | Oxygen content | 0~30%VOL | ±3%FS | 0.1%VOL | VOL | -20℃-+50℃ | 5-95%RH non-condensing |
QT6 | Negative oxygen ions | 0~100,000/cm³ | ±10% | 10pcs/cm³ | Pieces/cm³ | +10℃-+70℃ | 10-70%RH without condensation |
QT7 | Hydrogen sulfide | 0-100PPM | ±2PPM | 1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
QT8 | Methane | 0-100%LEL | ≤±3% | 1%LEL | LEL | -20℃-+50℃ | 10-95%RH non-condensing |
QT9 | TVOC | 0-100PPM | 55±15 nA/ppm | 1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
QT10 | Ammonia | 0-100PPM | ±4PPM | 1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
QT11 | Nitric Oxide | 0-250PPM | -2~10PPM | 1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
QT12 | formaldehyde | 0-10PPM | <1PPM | 0.1PPM | PPM | -20℃-+50℃ | 10-95%RH non-condensing |
2. Nitrogen dioxide sensor product dimensions
Related article
-
What is the best Agricultural Weather Stations company?
2024-08-22 -
Small meteorological monitoring stations for agriculture
2024-07-09 -
Quantifying Ecological Benefits with Data, Negative (Oxygen) Ion Monitoring System for Parks
2024-07-30 -
Portable Weather Station "Highlights"
2024-01-31 -
Agricultural Environment Monitoring System for more scientific agricultural production
2024-07-26 -
Advantages of Atmospheric Negative Oxygen Ion Monitoring System
2024-02-05 -
The Versatile Portable Weather Station: Always by Your Side
2024-10-25 -
Microclimate monitoring equipment for agriculture
2024-07-12