Product
Recommended article
- Portable Weather Station: Your Pocket-Sized Environmental Companion
- FT-CQX5 Micro Weather Station: Meteorological Monitoring at Your Fingertips
- Essential Meteorological Parameters: The Foundation of Weather Forecasting and Climate Analysis
- Fengtu's Vehicle-Mount Weather Station: Air Pollution Monitoring Technology
- Harnessing the Power of Negative Oxygen Ions for Healthier Environments
- Enhancing Air Pollution Control with Grid-Based Regulation and High-Resolution Monitoring
Contact us
Shandong Fengtu IOT Technology Co., Ltd
Sales Manager:Ms. Emily Wang
Cel,Whatsapp,Wechat:+86 15898932201
Email:info@fengtutec.com
Add:No. 155 Optoelectronic Industry Accelerator, Gaoxin District, Weifang, Shandong, China
Power Quality Monitoring Equipment
Model:FT-6500
Brand:fengtu
Related products
1.Power Quality Monitoring Equipment Product Introduction
Power Quality Monitoring Equipment Power quality monitoring and energy efficiency evaluation for power systems and equipment under different operating conditions.Handheld Power Quality Monitoring Equipment can record and analyze all power quality parameters such as harmonics, voltage, current, frequency, fluctuation, flicker, power and three-phase imbalance on site, and has advanced measurement functions such as power transient monitoring, wave recording analysis, energy efficiency loss evaluation, inverter measurement, etc. The measurement results provide free host computer analysis software for secondary analysis, providing accurate data basis for power quality management of power grid.
2. Core Technical Indicators of Power Quality Monitoring Equipment
Flicker accuracy: ±5%
Voltage accuracy: 0.1%
Frequency: 50Hz/60Hz
Measuring cycle: 10/12 cycles
Frequency width: 42.5-69Hz
Voltage unbalance: ±0.2%
Current unbalance: ±0.5%
Maximum sampling frequency: 200kHz
Current accuracy: 0.1% + CT accuracy
Power factor accuracy: 0.5% + CT accuracy
Voltage test range: 0-1000V, instantaneous 6000V
Data storage: 8G
Working hours: ≥5h
IP rating: IP53
Support manual/automatic recording
Recording time: 10s-10min
Recording cycle: 10/12 cycles
Minimum recording time interval: 0.2s
USB transmission speed: ≥17M/S
Harmonic measurement: 50th/50Hz-2500Hz
Waveform sampling points: 128/256/512 points/cycle
Safety level: 600V CAT IV/1000V CAT III
Chinese and English interface settings
Support multiple transformer brands
Inverter measurement: single phase/three phase
Energy Loss Analysis: Monetary Statistics
Free professional host computer analysis software
Transient monitoring: Capture the shortest 50us waveform
Complies with IEC61000-4-7 harmonic measurement standard
Complies with IEEE 1459, DIN 40110 algorithms
Complies with IEC61000-4-15 flicker measurement standard
Interharmonic measurement: 50th/25Hz-2475Hz
High harmonics: 35th/2100Hz-8900Hz
3. Advanced Measurement Functions of Power Quality Monitoring Equipment
1. Waveform analysis
Supports 1-10min waveform recording function, supports custom sampling points to record original waveforms, and uses PC professional host analysis software to secondary analyze waveforms, which can more effectively analyze the causes of power grid failures.
2. Parameter statistics
Comprehensively record and analyze power quality parameters. The minimum recording interval is 0.2s. The recorded data can be used for secondary analysis by the host computer software, and can generate custom or national standard reports.
3. Transient monitoring
200kHz high-speed fixed-frequency sampling can capture the shortest 50us waveform instantaneous pulse and rapidly changing waveform data, while supporting lossless recording of transient events.
4.Energy efficiency loss assessment
It supports power decomposition, detailed statistics of power loss caused by various types of parameters, pollution assessment, and intuitively displays the economic losses caused by energy loss in the form of currency.
5. Inverter measurement
It can analyze the electrical parameters of single-phase/three-phase inverters, analyze and record the inverter's DC input, AC output, conversion efficiency and other parameters.
6. Oscilloscope
Display 4-channel voltage and current waveforms, support horizontal and vertical zooming, intuitively display waveform distortion, and understand the impact of high-order harmonics on signals.
4. Features of Power Quality Monitoring Equipment
1. Multi-regional standards
50Hz/60Hz power grid power frequency system measurement, Chinese and English language settings, customized multi-country phase sequence color standards and calculation methods to meet the needs of different users.
High precision, wide bandwidth, wide range
The measurement accuracy complies with IEC 61000-4-30 Class A standard, IEC61000-4-7 harmonic measurement, IEC61000-4-15 flicker measurement, and can measure up to 6000V instantaneous voltage. The maximum frequency of high-order harmonics can reach 9kHz.
2. Setup Wizard
Guide users to set parameters to meet basic measurement settings, solve the confusion of new users on how to set parameters, and provide visual guidance, which is simple and convenient.
3. Wiring verification
The unique wiring verification function guides users to connect correctly, prevents invalid records caused by wiring errors, and provides effective prompts for wiring errors.
4. Compatibility design
Supports current transformers of various brands in the industry.
5.IP53 grade structure
It has 1.5m drop protection capability and a protection level of up to IP53.
6. Data analysis software PQViewer
Power quality data analysis software (PQViewer) is a data analysis software that is compatible with power quality analyzers.
PQViewer can read the power quality data files collected and recorded by the analyzer, provide data analysis and statistics functions, and can export measurement data and reports that meet international standards, which helps to quickly and accurately locate power quality problems. Data Analysis Function
Statistical data analysis, showing the statistical results of voltage, current, power, frequency, harmonics and other data in the form of trend charts, and all power data status changes are clearly visible;
Harmonic analysis, which displays the statistical results of harmonic data in histograms and trend charts, and provides comprehensive information from detailed harmonic data to macroscopic results.
Event data analysis (transient events and steady-state alarm events), reporting the time, type and detailed data of the event, and can perform single-channel analysis and multi-channel comparative analysis of the power quality status at the time of the event;
Generate reports that meet national standards through simple operations
7. Data export and reporting
Export report content, can quickly output Excel format reports, trend charts, harmonic spectrum bar charts and ITIC curves, which are widely used in secondary analysis of measurement data with higher efficiency; Word format reports are also provided, table data and pictures can be viewed at the same time, rich in content, saving time.
Export raw data: export the recorded raw data in csv file, which is convenient for secondary data processing and analysis, and the results are accurate; the operation is simple and the export can be completed in two steps.
5. General parameters of Power Quality Monitoring Equipment
parameter | Parameter Type | describe | |
mechanical | Dimensions (mm) | 263×168×65 | |
weight | About 2kg | ||
environment | working environment | 0℃~+45℃, humidity below 90rh% | |
Storage Environment | -20℃~+50℃, humidity below 95rh% (non-condensing) | ||
storage | type | TF card (built-in) | SD card (external) |
capacity | 8GB | 8G (maximum support 128G) | |
power supply | Adapter input | 110V-240V, 50Hz | |
Adapter output | 15V, 3A | ||
Battery | type | Rechargeable polymer lithium-ion battery, 5000mAh | |
Battery operating time | ≥5h | ||
Battery charging time | Minimum 5h (ambient temperature 25℃) | ||
Power saving function | LCD backlight brightness is adjustable, standby time is adjustable | ||
show | size | 112.8×84.6mm | |
color | 260,000 colors | ||
Resolution | 640×480 |
6. Power Quality Monitoring Equipment Measurement Parameters
Function | Parameter Type | describe |
Recorder | Oscilloscope | Real-time waveforms of voltage and current of phases A, B, C, and N |
Voltage Current Frequency | Frequency value, voltage RMS, voltage half-wave RMS, voltage positive peak, voltage negative peak, voltage waveform factor, current RMS, current half-wave RMS, current positive peak, current negative peak, current waveform factor | |
Power and battery | Active power, reactive power, apparent power, power factor, displacement power factor, active electrical energy, reactive electrical energy, apparent power electrical energy | |
Voltage harmonics | THD, DC, 1-50th harmonic, 0-49th interharmonic, 1-35th higher harmonic | |
Current harmonics | THD, DC, KF, 1-50th harmonics, 0-49th interharmonics, 1-35th higher harmonics | |
Harmonic Power | THD, DC, 1st-50th harmonic power | |
Flicker | PST (short flicker), PLT (long flicker) | |
unbalanced | Positive sequence voltage, positive sequence current, negative sequence voltage, negative sequence current, zero sequence voltage, zero sequence current, unbalance | |
Energy loss | Active, reactive, apparent power decomposition, line loss power, line loss cost, pollution assessment | |
Demand | Demand | |
record | Voltage surge, voltage sag, voltage interruption, surge current, short flicker over limit, long flicker over limit, voltage over limit, voltage under limit, frequency over limit, frequency under limit, steady-state voltage fluctuation, voltage unbalance over limit, voltage THD over limit, voltage 1-50 harmonic over limit, current 2-50 harmonic over limit | |
Inverter | DC | DC voltage, DC current, DC power, ripple voltage, ripple voltage content |
comminicate | Frequency, voltage RMS, current RMS, total apparent power, total active power, total power factor, fundamental power, fundamental power factor | |
efficiency | Conversion efficiency | |
Transient | Voltage | Voltage RMS, voltage half-wave RMS, voltage positive peak, voltage negative peak |
Current | Current RMS, current half-wave RMS, current positive peak, current negative peak | |
frequency | frequency | |
record | Voltage surge, voltage drop, voltage interruption | |
Monitor | Monitor | Voltage effective value, 1-50th voltage harmonics, PLT, voltage sag, voltage swell, voltage interruption, steady-state voltage variation, voltage imbalance |
Related article
-
Automatic Farmland Weather Station
2024-08-20 -
How many parameters can a park anion monitoring system measure?
2024-07-24 -
Role of grassland weather stations
2024-03-05 -
Fengtu's Vehicle-Mount Weather Station: Air Pollution Monitoring Technology
2024-11-01 -
Small meteorological monitoring stations for agriculture
2024-07-09 -
Windway Meteorological Observatory
2024-08-08 -
Features Galore: Key Advantages of Environmental Monitoring Station FT - FZ3
2024-10-12 -
What are forest fire risk factor collection stations for?
2024-07-17