Power quality detector

Power quality detector

Model:FT-6500

Brand:fengtu

The Power quality detector can record and analyze all power quality parameters such as harmonics, voltage, current, frequency, fluctuation, flicker, power and three-phase unbalance on site.

1. Power quality detector product introduction

Handheld Power quality detector, it can record and analyze all power quality parameters such as harmonics, voltage, current, frequency, fluctuation, flicker, power and three-phase imbalance on site. It also has power transient monitoring, wave recording analysis, energy efficiency Advanced measurement functions such as loss assessment and inverter measurement. The measurement results are provided with free host computer analysis software for secondary analysis, providing accurate data basis for power grid power quality management.

2. Core technical indicators of Power quality detector

Flicker accuracy: ±5%

Voltage accuracy: 0.1%

Frequency: 50Hz/60Hz

Measurement cycle: 10/12 cycles

Frequency width: 42.5-69Hz

Voltage imbalance: ±0.2%

Current imbalance: ±0.5%

Maximum sampling frequency: 200kHz

Current accuracy: 0.1%+CT accuracy

Power factor accuracy: 0.5%+CT accuracy

Voltage test range: 0-1000V, instantaneous 6000V

Data storage: 8G

Working time: ≥5h

IP rating: IP53

Support manual/automatic wave recording

Recording time: 10s-10min

Recording period: 10/12 periods

Minimum recording time interval: 0.2s

USB transfer speed: ≥17M/S

Harmonic measurement: 50th/50Hz-2500Hz

Recording sampling points: 128/256/512 points/period

Safety level: 600V CAT IV/1000V CAT III

Chinese and English interface settings

Support multiple transformer brands

Inverter measurement: single phase/three phase

Energy Loss Analysis: Monetary Statistics

Free professional PC analysis software

Transient monitoring: capture the shortest 50us waveform

Comply with IEC61000-4-7 harmonic measurement standard

Comply with IEEE 1459, DIN 40110 algorithm

Comply with IEC61000-4-15 flicker measurement standard

Interharmonic measurement: 50th/25Hz-2475Hz

Higher harmonics: 35th/2100Hz-8900Hz

3. Advanced measurement function of Power quality detector

1. Wave recording analysis

Supports 1-10min wave recording function, supports custom sampling points to record original waveforms, and PC professional host computer analysis software to secondary analyze waveforms to more effectively analyze the causes of power grid failures.

2. Parameter statistics

Comprehensive recording and data analysis of power quality parameters. The minimum recording interval is 0.2s, and the recorded data can be used for secondary analysis by the host computer software, and customized or national standard reports can be generated.

3. Transient monitoring

200kHz high-speed fixed-frequency sampling can capture the shortest 50us waveform instantaneous pulse, capture rapidly changing waveform data, and supports lossless recording of transient events.

4.Energy efficiency loss assessment

It supports power decomposition, detailed statistics of power loss caused by various types of parameters, supports pollution assessment, and intuitively displays the economic losses caused by energy loss in the form of currency.

5.Inverter measurement

It can perform electrical parameter analysis on single-phase/three-phase inverters, and analyze and record parameters such as DC input, AC output, and conversion efficiency of the inverter.

6.Oscilloscope

Displays 4-channel voltage and current waveforms, supports horizontal and vertical scaling, intuitively displays waveform distortion, and understands the impact of high-order harmonics on signals.

4. Features of Power quality detector

1.Multi-regional standards

50Hz/60Hz power grid power frequency system measurement, Chinese and English language settings, customized multi-national phase sequence color standards and calculation methods to meet different user needs.

High precision, wide frequency band, wide range

The measurement accuracy complies with IEC 61000-4-30 Class A standard, IEC61000-4-7 harmonic measurement, and IEC61000-4-15 flicker measurement. The maximum instantaneous voltage can be measured up to 6000V, and the maximum frequency of high-order harmonics can reach 9kHz.

2.Setup Wizard

Guide users to set parameters to meet basic measurement settings and solve the confusion of new users not knowing how to set parameters. Visual guidance is simple and convenient.

3. Wiring verification

The original wiring verification function guides users to connect correctly, prevents invalid records caused by wiring errors, and provides effective prompts for wiring errors.

4.Compatibility design

Supports multiple brands of current transformers in the industry.

5.IP53 level structure

It has 1.5m anti-fall protection capability and a protection level of up to IP53.

6. Data analysis software PQViewer

Power quality data analysis software (PQViewer) is a data analysis software supporting the power quality analyzer.

PQViewer can read the power quality data files collected and recorded by the analyzer, provide data analysis functions and data statistics functions, and can export measurement data and export reports that comply with international standards, helping to quickly and accurately locate power quality problems. Data analysis function

Statistical data analysis displays the statistical results of voltage, current, power, frequency, harmonics and other data in the form of trend graphs, and all power data status changes can be seen at a glance;

Harmonic analysis displays the statistical results of harmonic data with histograms and trend charts, from detailed harmonic data to macroscopic results, all under control;

Event data analysis (transient events and steady-state alarm events), reports the time, type and detailed data of the event, and can perform single-channel analysis and multi-channel comparative analysis of the power quality status at the time of the event;

Reports that comply with national standards can be generated through simple operations

7. Data export and reporting

Export report content, which can quickly output Excel format reports, trend charts, harmonic spectrum histograms and ITIC curves, which are widely used in secondary analysis of measurement data and are more efficient; Word format reports are also provided, and tabular data and pictures can be viewed at the same time. Rich content, save time.

Export the original data and export the recorded original data as a csv file, which facilitates secondary data processing and analysis, and the results are accurate; the operation is simple and the export can be completed in two steps.

5. General parameters of Power quality detector

parameterParameter Typedescribe
mechanicalDimensions (mm)263×168×65
weightabout 2kg
environmentworking environment0℃~+45℃, humidity below 90rh%
Storage environment-20℃~+50℃, humidity below 95rh% (non-condensing)
storagetypeTF card (built-in)SD card (external)
capacity8GB8G (maximum support 128G)
power supplyadapter input110V-240V, 50Hz
adapter output15V, 3A
BatterytypeRechargeable polymer lithium-ion battery, 5000mAh
Battery working time≥5h
Battery charging timeMinimum 5h (ambient temperature 25℃)
Power saving functionLCD backlight brightness is adjustable and standby time is adjustable
showsize112.8×84.6mm
color260,000 colors
resolution640×480

6. Power quality detector measurement parameters

FunctionParameter Typedescribe
RecorderOscilloscopeReal-time waveforms of voltage and current of each phase A, B, C and N
Voltage current frequencyFrequency value, voltage effective value, voltage half-wave effective value, voltage positive peak value, voltage negative peak value, voltage form factor, current effective value, current half-wave effective value, current positive peak value, current negative peak value, current waveform factor
Power and batteryActive power, reactive power, apparent power, power factor, displacement power factor, active electrical energy, reactive electrical energy, apparent power electrical energy
Voltage harmonicsTHD, DC, 1-50 harmonics, 0-49 inter-harmonics, 1-35 higher harmonics
Current harmonicsTHD, DC, KF, 1-50th harmonic, 0-49th harmonic, 1-35th harmonic
Harmonic powerTHD, DC, 1-50th harmonic power
FlickerPST (short flicker), PLT (long flicker)
unbalancedPositive sequence voltage, positive sequence current, negative sequence voltage, negative sequence current, zero sequence voltage, zero sequence current, unbalance
energy lossActive power, reactive power, apparent power decomposition, line loss power, line loss cost, pollution assessment
demanddemand
recordVoltage swell, voltage sag, voltage interruption, surge current, short flicker limit violation, long flicker limit violation, upper voltage limit violation, lower voltage limit violation, upper frequency limit violation, lower frequency limit violation, steady-state voltage fluctuation, voltage imbalance Over-limit, voltage THD over-limit, voltage 1-50th harmonic over-limit, current 2-50 harmonic over-limit
InverterDCDC voltage, DC current, DC power, ripple voltage, ripple voltage content rate
comminicateFrequency, voltage effective value, current effective value, total apparent power, total active power, total power factor, fundamental power, fundamental power factor
efficiencyConversion efficiency
TransientVoltageVoltage effective value, voltage half-wave effective value, voltage positive peak value, voltage negative peak value
currentCurrent effective value, current half-wave effective value, current positive peak value, current negative peak value
frequencyfrequency
recordVoltage swells, voltage sags, voltage interruptions
monitormonitorVoltage effective value, 1-50 voltage harmonics, PLT, voltage sag, voltage swell, voltage interruption, steady-state voltage change, voltage imbalance